Direct Outside Air Cooling Solutions

FA/CW Cooling Solutions W Series Cooling Range Technical Data Notes: 1. Nett sensible cooling takes into account heat gain from the fans and is based on typical external airflow resistance of 100Pa. 2. All free cooling units include a motorised damper on outside air & return air connections. 3. Electric heaters for dehumidification etc. are available to suit application. 4. Rooms require pressure relief devices when fresh air free cooling units are operating on full outside air mode. 5. Filters - G4 standard but higher efficiency pleated panel filters available. 6. Down-flow unit plinths are supplied separately and can be manufactured to suit varying floor void depths. 7. All units require a three phase and neutral power supply. 8. Full sound spectrumdata for each fan is available on request. 9. Humidity control options available. Model W30DF W45DF W55DF W66DF W100DF Electrical Supply (V/~/Hz) 400V/3ph/50Hz 400V/3ph/50Hz 400V/3ph/50Hz 400V/3ph/50Hz 400V/3ph/50Hz Supply FLC with EC Fans (Amps) 5.2 10.8 9.6 10.9 15.8 Electrical Details Large Data Centre cooling solutions For larger Data Centres with a high density cooling requirement, we will design and manufacture bespoke, fully packaged, free outside air cooling, external or rooftop packaged solutions, each cooling unit delivering up to 400kW of cooling capacity. Direct Replacement cooling solutions We design and manufacture high efficiency ‘direct replacement’ units (DX and CW) to replicate the existing connection services - to ensure a quick, easy and cost efficient replacement. Internal components of existing equipment can also be upgraded/modernised for improved efficiency/output, where required. Containerised cooling solutions We offer a design and manufacture capability to suit the client’s physical and capacity requirements. We can manufacture the weatherproof housing and fit out with the necessary cooling system, electrical installation, fire suppression, etc - requiring the client to simply install their chosen IT equipment. Bespoke cooling solutions Weatherite can provide complete bespoke solutions that meet the client’s requirements exactly. Adiabatic cooling solutions Weatherite is in the final design stage of producing our packaged direct and indirect adiabatic cooling solutions. The adiabatic system can, if necessary, incorporate a DX standby/supplementary system. CCP and CCHP solutions Weatherite’s Combined Cooling and Power (CCP) or Combined Cooling, Heating and Power (CCHP) Energy Centres provide power, cooling and where required, heating for all types of applications including Data Centres - all from one self contained, localised unit. Additional cooling capabilities from the experts Weatherite Group is one of the UK’s leading air conditioning organisations and has over 25 years’ experience in delivering energy efficient cooling solutions for IT environments. CPD presentation Weatherite has a CIBSE approved CPDpresentation on the effective use of Economiser Direct Fresh Air Free Cooling which can presented at your office. For more information call: 0121 655 2266. Air Containment solutions Weatherite can incorporate purpose built containment systems to suit the Data Centre configurations. 12 °C ..... 26 °C 12 °C ..... 26 °C 12 °C ..... 26 °C 12ºC ... 26ºC 6ºC ... 13ºC 12ºC ... 20ºC Model W30 DF W45 DF W55DF W66 DF W100 DF Delta T (R/A - S/A) ∆T 10 12 10 12 10 12 10 12 10 12 Sensible Cooling Duty kW 27.5 33 42.3 50.8 50.3 60.4 60.5 72.6 89 106.8 Supply Air Temperature Range ºC CHW INTemperature Range ºC CHWOUT Temperature Range ºC Supply Air Volume m 3 /s 2.27 3.5 4.16 5 7.36 CHW Flow Rate Range l/s 1.1 l/s ... 1.6 l/s 1.7 l/s ... 2.4 l/s 2.0 l/s ... 2.9 l/s 2.4 l/s ... 3.5 l/s 3.5 l/s ... 5.1 l/s Number of Supply Fans 2 2 2 2 3 Configuration Down-flow Down-flow Down-flow Down-flow Down-flow UnitWidth mm 1,640 1,940 1,940 2,340 3,140 Unit Height (exc. plinth) mm 1,950 2,150 2,400 2,400 2,450 Unit Depth mm 850 1,000 1,000 1,000 1,000 UnitWeight kg 525 600 650 700 1,000 2,430 Performance

RkJQdWJsaXNoZXIy NDA5MjY=